CVE-2025-52952
Unknown Unknown - Not Provided
BaseFortify

Publication date: 2025-07-11

Last updated on: 2025-07-15

Assigner: Juniper Networks, Inc.

Description
An Out-of-bounds Write vulnerability in the connectivity fault management (CFM) daemon of Juniper Networks Junos OS on MX Series with MPC-BUILTIN, MPC1 through MPC9 line cards allows an unauthenticated adjacent attacker to send a malformed packet to the device, leading to an FPC crash and restart, resulting in a Denial of Service (DoS). Continued receipt and processing of this packet will create a sustained Denial of Service (DoS) condition. This issue affects Juniper Networks: Junos OS: * All versions before 22.2R3-S1, * from 22.4 before 22.4R2. This feature is not enabled by default.
CVSS Scores
EPSS Scores
Probability:
Percentile:
Meta Information
Published
2025-07-11
Last Modified
2025-07-15
Generated
2026-05-07
AI Q&A
2025-07-11
EPSS Evaluated
2026-05-05
NVD
EUVD
Affected Vendors & Products
Showing 2 associated CPEs
Vendor Product Version / Range
juniper junos 22.4
juniper junos 22.2r3-s1
Helpful Resources
Exploitability
CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-787 The product writes data past the end, or before the beginning, of the intended buffer.
Attack-Flow Graph
AI Powered Q&A
Can you explain this vulnerability to me?

This vulnerability is an Out-of-bounds Write in the connectivity fault management (CFM) daemon of Juniper Networks Junos OS on MX Series devices with certain line cards. An unauthenticated attacker adjacent to the device can send a specially crafted malformed packet that causes the device's FPC (Flexible PIC Concentrator) to crash and restart, leading to a Denial of Service (DoS).


How can this vulnerability impact me? :

The impact of this vulnerability is a Denial of Service (DoS) condition on affected Juniper MX Series devices. The device's FPC will crash and restart repeatedly when processing the malformed packets, potentially disrupting network operations and availability.