CVE-2025-40819
Unknown Unknown - Not Provided
BaseFortify

Publication date: 2025-12-09

Last updated on: 2025-12-10

Assigner: Siemens AG

Description
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications do not properly validate license restrictions against the database, allowing direct modification of the system_ticketinfo table to bypass license limitations without proper enforcement checks. This could allow with database access to circumvent licensing restrictions by directly modifying database values and potentially enabling unauthorized use beyond the permitted scope.
CVSS Scores
EPSS Scores
Probability:
Percentile:
Meta Information
Published
2025-12-09
Last Modified
2025-12-10
Generated
2026-05-07
AI Q&A
2025-12-09
EPSS Evaluated
2026-05-05
NVD
EUVD
Affected Vendors & Products
Showing 3 associated CPEs
Vendor Product Version / Range
siemens sinema_remote_connect_server 3.1
siemens sinema_remote_connect_server to 3.2 (inc)
siemens sinema_remote_connect_server 3.2
Helpful Resources
Exploitability
CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-863 The product performs an authorization check when an actor attempts to access a resource or perform an action, but it does not correctly perform the check.
Attack-Flow Graph
AI Powered Q&A
Can you explain this vulnerability to me?

This vulnerability exists in SINEMA Remote Connect Server versions before V3.2 SP4, where the application does not properly validate license restrictions against its database. An attacker with database access can directly modify the system_ticketinfo table to bypass license limitations, effectively circumventing licensing enforcement and potentially enabling unauthorized use beyond what is permitted.


How can this vulnerability impact me? :

The impact of this vulnerability is that an attacker with access to the database can bypass license restrictions, allowing unauthorized use of the software beyond the licensed scope. This could lead to unlicensed usage, potential financial loss, and violation of software usage agreements.


What immediate steps should I take to mitigate this vulnerability?

The immediate step to mitigate this vulnerability is to update all affected SINEMA Remote Connect Server versions to V3.2 SP4 or later. Additionally, implement general security measures such as protecting network access with appropriate mechanisms and configuring the environment according to Siemens' operational guidelines for Industrial Security. [1]