CVE-2026-26034
Received
Received - Intake
Incorrect Default Permissions in MUMC Enable SYSTEM-Level Code Execution
Publication date: 2026-03-05
Last updated on: 2026-03-09
Assigner: JPCERT/CC
Description
Description
UPS Multi-UPS Management Console (MUMC) version 01.06.0001 (A03) contains an Incorrect Default Permissions (CWE-276) vulnerability that allows an attacker to execute arbitrary code with SYSTEM privileges by causing the application to load a specially crafted DLL.
CVSS Scores
EPSS Scores
| Probability: | |
| Percentile: |
Meta Information
Affected Vendors & Products
| Vendor | Product | Version / Range |
|---|---|---|
| dell | ups_multi-ups_management_console | 01.06.0001_(a03) |
Helpful Resources
Exploitability
| CWE ID | Description |
|---|---|
| CWE-428 | The product uses a search path that contains an unquoted element, in which the element contains whitespace or other separators. This can cause the product to access resources in a parent path. |
| CWE-276 | During installation, installed file permissions are set to allow anyone to modify those files. |