CVE-2026-5768
Unauthenticated BLE Access in Frontier X2 Device
Publication date: 2026-05-29
Last updated on: 2026-05-29
Assigner: ICS-CERT
Description
Description
CVSS Scores
EPSS Scores
| Probability: | |
| Percentile: |
Meta Information
Affected Vendors & Products
| Vendor | Product | Version / Range |
|---|---|---|
| fourth_frontier | frontier_x2 | * |
| fourth_frontier | frontier_x_plus | * |
| fourth_frontier | csafpid_0001 | * |
| fourth_frontier | csafpid_0002 | * |
| fourth_frontier | csafpid_0003 | * |
Helpful Resources
Exploitability
| CWE ID | Description |
|---|---|
| CWE-306 | The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. |
Attack-Flow Graph
AI Powered Q&A
Can you explain this vulnerability to me?
The vulnerability in the Frontier X2 device allows attackers within Bluetooth Low Energy (BLE) range to read and write critical device characteristics without needing to authenticate or pair with the device.
This lack of authentication enables unauthorized control over device functions such as starting or stopping activities, triggering vibrations, causing denial-of-service conditions, and fuzzing characteristic values to cause unexpected behavior.
Additionally, the Frontier X mobile application does not properly authenticate BLE devices, allowing attackers to impersonate legitimate Frontier X2 devices by cloning BLE advertisements and expected characteristics.
This impersonation lets attackers manipulate activity states and inject fabricated health telemetry data like breathing rate, heart rate, and strain into the mobile app.
How can this vulnerability impact me? :
Exploitation of this vulnerability can lead to unauthorized control of the Frontier X2 device, including starting or stopping activities and triggering device vibrations without user consent.
Attackers can cause denial-of-service conditions, disrupting normal device operation.
They can also inject false health data such as fabricated heart rate or breathing rate readings into the mobile application, potentially misleading users or healthcare providers.
Overall, this can result in compromised device integrity, availability, and confidentiality, posing risks to patient safety and trust in the device.
How can this vulnerability be detected on my network or system? Can you suggest some commands?
This vulnerability involves unauthorized BLE read/write access to critical GATT characteristics on Frontier X2 devices without authentication. Detection would involve monitoring Bluetooth Low Energy (BLE) traffic for unusual or unauthorized access attempts to these GATT characteristics.
Specifically, detection could focus on identifying BLE devices attempting to read or write to the Frontier X2 device's GATT handles without proper pairing or authorization.
While no specific commands are provided in the resources, typical BLE scanning and monitoring tools such as 'bluetoothctl' on Linux or specialized BLE sniffers could be used to observe BLE advertisements and connections.
- Use 'bluetoothctl' to scan for BLE devices and check for multiple connections or unexpected devices advertising Frontier X2 characteristics.
- Use BLE sniffing tools (e.g., Ubertooth One, Wireshark with BLE capture) to monitor BLE traffic and detect unauthorized GATT read/write operations.
- Look for cloned BLE advertisements or unexpected connections to the Frontier X mobile application, which may indicate impersonation attempts.
What immediate steps should I take to mitigate this vulnerability?
Immediate mitigation steps include limiting device exposure and controlling BLE connections to reduce the risk of unauthorized access.
- Connect Frontier X2 devices to only one mobile application at a time to prevent multiple unauthorized connections.
- Use the Frontier X mobile application before starting any activities to ensure proper device interaction.
- Minimize network exposure of the devices by isolating control systems behind firewalls.
- Use secure remote access methods such as VPNs to protect device communication.
Additionally, users are advised to contact Fourth Frontier for assistance and updates regarding patches or fixes.
How does this vulnerability affect compliance with common standards and regulations (like GDPR, HIPAA)?:
The vulnerability in the Frontier X2 device allows unauthorized access and manipulation of sensitive health-related data such as heart rate, breathing rate, and other clinical readings. This unauthorized access and data manipulation could lead to violations of data integrity and confidentiality requirements mandated by regulations like HIPAA and GDPR.
Specifically, the ability for attackers to inject fabricated health telemetry and control device functions without authentication undermines the protection of personal health information, which is critical for compliance with these standards.
Furthermore, the lack of proper BLE device authentication in the Frontier X mobile application increases the risk of impersonation attacks, potentially exposing personal health data to unauthorized parties, which could result in non-compliance with privacy and security obligations under these regulations.