CVE-2026-56569
Received Received - Intake

Sensitive Data Exposure in HCL iControl

Vulnerability report for CVE-2026-56569, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-07-31

Last updated on: 2026-07-31

Assigner: HCL Software

Description

HCL iControl was affected by Sensitive Data Exposure vulnerabilities. It involves the public exposure of internal configuration files due to improper web server or application hardening.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-07-31
Last Modified
2026-07-31
Generated
2026-07-31
AI Q&A
2026-07-31
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
hcl icontrol *

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-497 The product does not properly prevent sensitive system-level information from being accessed by unauthorized actors who do not have the same level of access to the underlying system as the product does.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

HCL iControl had Sensitive Data Exposure vulnerabilities due to improper web server or application hardening. This allowed internal configuration files to be publicly exposed.

Detection Guidance

To detect this vulnerability, check for exposed configuration files on HCL iControl systems. Look for files like /config/bigip.conf or /config/bigip_base.conf accessible via HTTP/HTTPS. Use commands like curl to test URLs such as http://<target>/config/bigip.conf or https://<target>/tmui/login.jsp. Verify if sensitive data like passwords or internal IPs are exposed.

Impact Analysis

Attackers could access sensitive internal configuration files, potentially exposing confidential system details or credentials. This could lead to further attacks or data breaches.

Compliance Impact

This vulnerability involves sensitive data exposure due to improper web server or application hardening, which could lead to unauthorized access to internal configuration files. Such exposure may violate data protection requirements under GDPR and HIPAA by compromising confidentiality of personal or health information.

Mitigation Strategies

Immediately restrict access to HCL iControl by reviewing and tightening web server or application configurations. Ensure sensitive configuration files are not publicly accessible and apply proper hardening measures to prevent exposure.