CVE-2026-61498
Undergoing Analysis Undergoing Analysis - In Progress

Unauthenticated OS Command Injection in Vitec Flamingo

Vulnerability report for CVE-2026-61498, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-07-13

Last updated on: 2026-07-14

Assigner: VulnCheck

Description

Vitec Flamingo 4.12.2 contains an unauthenticated OS command injection vulnerability in the admin/ajax/gen_graphs.php endpoint that allows remote unauthenticated attackers to execute arbitrary commands by supplying shell metacharacters in the start, end, key, or format HTTP GET parameters. Attackers can exploit the lack of input sanitization in the graph generation script, which passes user-supplied values directly to shell commands via passthru(), to execute arbitrary OS commands with root privileges due to the web server context having passwordless sudo access.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-07-13
Last Modified
2026-07-14
Generated
2026-08-03
AI Q&A
2026-07-14
EPSS Evaluated
2026-08-01
NVD
EUVD

Affected Vendors & Products

Showing 2 associated CPEs
Vendor Product Version / Range
vitec flamingo 4.12.2
vitec flamingo to 4.12.2 (inc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-78 The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

CVE-2026-61498 is an unauthenticated OS command injection vulnerability in Vitec Flamingo version 4.12.2. It affects the admin/ajax/gen_graphs.php endpoint.

Remote attackers can exploit this flaw without authentication by injecting shell metacharacters into specific HTTP GET parameters: start, end, key, or format. The vulnerability occurs because the graph generation script does not properly sanitize user-supplied input before passing it to shell commands via the passthru() function.

Due to the web server running with passwordless sudo privileges, successful exploitation allows attackers to execute arbitrary OS commands with root-level privileges.

Detection Guidance

To detect the CVE-2026-61498 vulnerability on your network or system, you can check for the presence of the vulnerable endpoint and test for command injection.

  • Verify if the Vitec Flamingo version 4.12.2 or earlier is running by checking the software version in the admin interface or via HTTP headers.
  • Check for the existence of the vulnerable endpoint by accessing the following URL: http://[target]/admin/ajax/gen_graphs.php. If the endpoint is accessible, the system may be vulnerable.
  • Test for command injection by sending a request with shell metacharacters in the GET parameters (start, end, key, or format). For example: http://[target]/admin/ajax/gen_graphs.php?start=1;id&end=2. If the response includes the output of the 'id' command, the system is vulnerable.
  • Use a network scanning tool like curl or Burp Suite to send crafted requests and analyze responses for signs of command execution.
  • Monitor network traffic for unusual activity targeting the /admin/ajax/gen_graphs.php endpoint, especially requests containing shell metacharacters.
Impact Analysis

This vulnerability can have severe impacts if exploited:

  • Complete system compromise: Attackers can execute arbitrary commands on the affected Vitec Flamingo system with root privileges.
  • Unauthorized access: Since no authentication is required, attackers can exploit this remotely over a network.
  • Data theft or manipulation: Attackers could access, modify, or delete sensitive data stored on or accessible through the system.
  • Network propagation: The compromised system could be used as a pivot point to attack other systems on the same network.
  • Disruption of services: Attackers could disrupt IPTV distribution services, affecting live TV streams and video distribution across an organization.

The high CVSS score of 9.8 (v3.1) indicates this is a critical vulnerability with potential for significant damage.

Compliance Impact

This vulnerability can impact compliance with several standards and regulations:

  • GDPR (General Data Protection Regulation): If the affected system processes or stores personal data of EU citizens, a breach could lead to unauthorized access or disclosure of this data. This may result in violations of GDPR's data protection principles, potentially leading to significant fines (up to 4% of global annual revenue or €20 million, whichever is higher).
  • HIPAA (Health Insurance Portability and Accountability Act): If the Vitec Flamingo system is used in a healthcare environment and handles protected health information (PHI), exploitation of this vulnerability could lead to unauthorized access to PHI. This would constitute a breach under HIPAA, potentially resulting in fines and mandatory corrective action plans.
  • PCI DSS (Payment Card Industry Data Security Standard): If the system is part of or connected to a network that processes payment card data, this vulnerability could lead to non-compliance with PCI DSS requirements for securing systems against unauthorized access.
  • ISO 27001: This standard requires organizations to implement appropriate security controls to protect information assets. The presence of this critical vulnerability would likely be considered a failure to meet several ISO 27001 controls, particularly those related to access control and system security.

Exploitation of this vulnerability could also lead to violations of sector-specific regulations, depending on the industry in which Vitec Flamingo is deployed (e.g., broadcasting, hospitality, or corporate environments). Organizations may face legal consequences, reputational damage, and loss of customer trust if this vulnerability is exploited.

Mitigation Strategies

To mitigate CVE-2026-61498, follow these immediate steps:

  • Apply the latest patch or update from Vitec as soon as it becomes available. Check Vitec's official website or security advisories for updates.
  • If no patch is available, restrict access to the /admin/ajax/gen_graphs.php endpoint by implementing network-level controls such as firewalls or access control lists (ACLs) to block external access.
  • Disable the vulnerable endpoint temporarily if it is not critical to operations. This can be done by renaming or removing the gen_graphs.php file.
  • Review and restrict the web server's sudo privileges to prevent passwordless sudo access, which exacerbates the impact of this vulnerability.
  • Monitor the system and network for signs of exploitation, such as unusual command execution or unauthorized access attempts.
  • Consider deploying a web application firewall (WAF) to filter malicious requests targeting the vulnerable endpoint.

Chat Assistant

Ask questions about this CVE
Hi! I’m here to help you understand CVE-2026-61498. Ask me anything about the vulnerability, its impact, or mitigation strategies.
0/70