CVE-2026-6890
Received Received - Intake

Default Credentials in Advantech ECU-1251D

Vulnerability report for CVE-2026-6890, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-07-31

Last updated on: 2026-07-31

Assigner: CSA

Description

A use of default credentials vulnerability in the Advantech ECU-1251D allows a remote attacker to gain unauthorised access to the device via SSH using the default root account with no password, as documented in the device manual. No prompt or guidance to change these credentials is provided during device configuration, increasing the risk of exploitation.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-07-31
Last Modified
2026-07-31
Generated
2026-07-31
AI Q&A
2026-07-31
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
advantech ecu-1251d *

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-UNKNOWN

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This vulnerability is a use of default credentials issue in the Advantech ECU-1251D device. It allows a remote attacker to gain unauthorized access via SSH using the default root account with no password. The device manual documents these credentials, and there is no prompt to change them during setup, increasing the risk of exploitation.

Detection Guidance

Check for devices with default credentials by attempting SSH login to Advantech ECU-1251D using the root account with no password. Use commands like 'ssh root@<device_ip>' to test access. Scan your network for Advantech ECU-1251D devices and verify if SSH is enabled with default settings.

Impact Analysis

An attacker could exploit this to gain full control over the device, potentially leading to unauthorized access to sensitive data, disruption of device operations, or further attacks on connected systems. The lack of password requirement makes exploitation straightforward.

Compliance Impact

This vulnerability could lead to non-compliance with GDPR or HIPAA due to unauthorized access risks. GDPR requires protection of personal data, and HIPAA mandates secure access to health information. Exploitation may result in data breaches, violating these regulations.

Mitigation Strategies

Immediately change the default root password on the Advantech ECU-1251D device to a strong, unique password. Disable SSH access if not required or restrict it to trusted IP addresses. Ensure all devices are updated to the latest firmware if patches are available.

Chat Assistant

Ask questions about this CVE
Hi! I’m here to help you understand CVE-2026-6890. Ask me anything about the vulnerability, its impact, or mitigation strategies.
0/70

EPSS Chart