CVE-2026-8989
Awaiting Analysis Awaiting Analysis - Queue

Unrestricted Access to Recovery Mode in Autel Maxi Charger Single Firmware

Vulnerability report for CVE-2026-8989, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-07-21

Last updated on: 2026-07-22

Assigner: CyberDanube

Description

Autel Maxi Charger Single firmware through V1.03.51 permits unrestricted access to the NXP i.MX6 recovery mode through exposed hardware recovery pins. An attacker with physical access can boot attacker-controlled code in memory and modify or extract firmware and other sensitive data.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-07-21
Last Modified
2026-07-22
Generated
2026-08-11
AI Q&A
2026-07-22
EPSS Evaluated
2026-08-09
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
autel maxi_charger_single to 1.03.51 (inc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-1244 The product uses physical debug or test interfaces with support for multiple access levels, but it assigns the wrong debug access level to an internal asset, providing unintended access to the asset from untrusted debug agents.
CWE-1191 The chip does not implement or does not correctly perform access control to check whether users are authorized to access internal registers and test modes through the physical debug/test interface.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This vulnerability affects Autel Maxi Charger Single firmware versions through V1.03.51. It allows unrestricted access to the NXP i.MX6 recovery mode via exposed hardware recovery pins. An attacker with physical access can exploit this to boot malicious code in memory, potentially modifying or extracting firmware and sensitive data.

Detection Guidance

This vulnerability requires physical access to the device to exploit exposed hardware recovery pins. It cannot be detected remotely via network commands. Check for unauthorized physical access to the device or signs of tampering with the recovery pins.

Impact Analysis

If you own or use an Autel Maxi Charger Single with affected firmware, an attacker with physical access could gain control over the device. This may lead to unauthorized firmware changes, data theft, or further compromise of connected systems.

Compliance Impact

This vulnerability allows physical access to modify or extract sensitive data, which could lead to unauthorized data access or breaches. This may violate GDPR's data protection requirements and HIPAA's safeguards for protected health information if the device handles such data.

Mitigation Strategies

Restrict physical access to the device to authorized personnel only. Ensure the device is stored in a secure location. Regularly inspect the device for signs of tampering or unauthorized access.