CVE-2026-16911
Analyzed Analyzed - Analysis Complete

Stack Buffer Overflow in IBM AIX and PowerVM VIOS

Vulnerability report for CVE-2026-16911, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-08-19

Last updated on: 2026-08-21

Assigner: IBM Corporation

Description

IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote authenticated attacker to execute arbitrary code due to a stack buffer overflow.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-08-19
Last Modified
2026-08-21
Generated
2026-09-09
AI Q&A
2026-08-20
EPSS Evaluated
2026-09-07
NVD
EUVD

Affected Vendors & Products

Showing 7 associated CPEs
Vendor Product Version / Range
ibm vios From 4.1.0 (inc) to 4.1.0.50 (exc)
ibm vios From 4.1.1.0 (inc) to 4.1.1.30 (exc)
ibm vios From 4.1.2.0 (inc) to 4.1.2.20 (exc)
ibm aix From 7.2.5 (inc) to 7.2.5.212 (inc)
ibm aix From 7.3.2 (inc) to 7.3.2.5 (inc)
ibm aix From 7.3.3 (inc) to 7.3.3.2 (inc)
ibm aix From 7.3.4 (inc) to 7.3.4.1 (inc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-121 A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This is a stack buffer overflow vulnerability in IBM AIX 7.2, 7.3, and IBM PowerVM VIOS 4.1. A remote authenticated attacker could exploit this to execute arbitrary code on the affected system.

Detection Guidance

This vulnerability involves a stack buffer overflow in IBM AIX 7.2, 7.3, and PowerVM VIOS 4.1. Detection requires checking system versions and applying IBM's official patches or updates. No specific commands are provided in the context to directly detect this issue.

Impact Analysis

An attacker could gain control of the system, steal data, install malware, or disrupt operations. This requires remote access and authentication, but could lead to severe system compromise.

Compliance Impact

This vulnerability could lead to unauthorized access to sensitive data, violating GDPR and HIPAA requirements for data protection and confidentiality. Organizations may face compliance penalties if exploited.

Mitigation Strategies

Apply IBM-provided patches or updates for AIX 7.2, 7.3, and PowerVM VIOS 4.1 immediately. Isolate affected systems if possible and restrict remote authenticated access until patched.

Chat Assistant

Ask questions about this CVE
Hi! I’m here to help you understand CVE-2026-16911. Ask me anything about the vulnerability, its impact, or mitigation strategies.
0/70

EPSS Chart