CVE-2026-66875
Received Received - Intake

Mira Hormone Monitor Firmware Remote Unauthenticated BLE Exploits

Vulnerability report for CVE-2026-66875, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-08-11

Last updated on: 2026-08-12

Assigner: ICS-CERT

Description

In the Mira hormone monitor device firmware v1.7.1.47 build 01070147, a remote unauthenticated attacker within BLE range (approximately 10–30 meters) can silently rebind the device to an attacker-controlled account, extract stored hormone measurements in cleartext, cause a denial-of-service via malformed or undocumented command opcodes, and passively track the user via a static random BLE address that never rotates.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-08-11
Last Modified
2026-08-12
Generated
2026-09-01
AI Q&A
2026-08-12
EPSS Evaluated
2026-08-31
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
mira hormone_monitor_device 1.7.1.47

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-306 The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This vulnerability affects the Mira hormone monitor device firmware v1.7.1.47. A remote unauthenticated attacker within Bluetooth Low Energy (BLE) range can silently rebind the device to their own account without user knowledge. They can then extract stored hormone measurements in cleartext, cause a denial-of-service by sending malformed or undocumented BLE commands, and track the user passively due to a static random BLE address that does not change.

Detection Guidance

Detecting this vulnerability requires checking for unauthorized BLE device bindings, static BLE addresses, and unusual hormone measurement data extraction. Use BLE scanning tools like hcitool or bluetoothctl to monitor nearby devices for static addresses and unexpected re-pairing attempts. Check device logs for malformed command opcodes or repeated connection attempts.

Impact Analysis

If you use the Mira hormone monitor device, an attacker within 10-30 meters could access your sensitive hormone data without your consent. They could also disrupt the device's functionality or track your movements over time due to the static BLE address.

Compliance Impact

This vulnerability likely violates GDPR due to unauthorized access to personal health data and HIPAA if the device is used in a covered healthcare context. It exposes sensitive health information without user consent, which is a direct violation of data protection requirements.

Mitigation Strategies

Immediately disable BLE connectivity on the Mira device if not in use. Update the firmware to the latest version if a patch is available. Restrict physical access to the device to prevent close-range attacks. Monitor network traffic for unauthorized data exfiltration attempts.