CVE-2026-78314
Received Received - Intake

SQL Injection in Delta DIAEnergie Allows Remote Code Execution

Vulnerability report for CVE-2026-78314, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-08-24

Last updated on: 2026-08-24

Assigner: Deltaww

Description

SQL Injection in Delta DIAEnergie v1.11.00.002 allows attacker to remote code execution.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-08-24
Last Modified
2026-08-24
Generated
2026-08-24
AI Q&A
2026-08-24
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 2 associated CPEs
Vendor Product Version / Range
delta_electronics diaenergie to 1.11.00.022 (exc)
delta_electronics diaenergie 1.11.00.022

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-89 The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

CVE-2026-78314 is a high-severity SQL injection vulnerability in Delta Electronics' DIAEnergie software version 1.11.00.002 and earlier. It allows attackers to remotely execute arbitrary code by injecting malicious SQL queries into the system.

Detection Guidance

Detecting SQL injection vulnerabilities like CVE-2026-78314 typically involves monitoring network traffic for suspicious SQL queries, inspecting application logs for unusual database access patterns, and using web application firewalls (WAFs) to filter malicious inputs. Commands may include checking web server logs for repeated error messages, using tools like SQLmap to test for injection points, or analyzing database logs for unauthorized queries.

Impact Analysis

This vulnerability can lead to unauthorized access, data manipulation, and complete system compromise. Attackers could steal sensitive data, alter or delete information, or disrupt operations without needing high privileges or user interaction.

Compliance Impact

This vulnerability likely violates compliance requirements for data protection standards like GDPR and HIPAA due to unauthorized data access and potential data breaches. Organizations using affected software must address it to maintain regulatory compliance.

Mitigation Strategies

Immediately update DIAEnergie to version v1.11.00.022 or later as recommended by Delta Electronics. Avoid exposing control systems to the internet, implement firewalls to restrict access, and use secure remote access methods like VPNs. Contact Delta technical support for the patch if automatic updates are unavailable.

Chat Assistant

Ask questions about this CVE
Hi! I’m here to help you understand CVE-2026-78314. Ask me anything about the vulnerability, its impact, or mitigation strategies.
0/70