CVE-2026-75998
Undergoing Analysis Undergoing Analysis - In Progress

Improper Access Control in Adobe ColdFusion

Vulnerability report for CVE-2026-75998, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-09-08

Last updated on: 2026-09-18

Assigner: Adobe Systems Incorporated

Description

ColdFusion is affected by an Improper Access Control vulnerability that could lead to arbitrary file system read. An attacker could exploit this vulnerability to access sensitive files and directories outside the intended access scope. Exploitation of this issue does not require user interaction.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-09-08
Last Modified
2026-09-18
Generated
2026-09-29
AI Q&A
2026-09-10
EPSS Evaluated
2026-09-27
NVD

Affected Vendors & Products

Showing 37 associated CPEs
Vendor Product Version / Range
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025
adobe coldfusion 2023
adobe coldfusion 2025

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-284 The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

ColdFusion has an Improper Access Control vulnerability allowing arbitrary file system read. Attackers can access sensitive files outside intended scope without user interaction.

Impact Analysis

This vulnerability could allow attackers to read sensitive files on the server, potentially exposing confidential data like configuration files, user credentials, or other restricted information.

Compliance Impact

This vulnerability could lead to unauthorized access to personal or sensitive data, violating GDPR and HIPAA compliance requirements for data protection and access controls.

Mitigation Strategies

Apply the latest security patches from Adobe for ColdFusion immediately to address the improper access control vulnerability. Review and restrict file system access permissions to limit exposure. Monitor network traffic for unusual file access patterns and disable unnecessary services.