CVE-2026-80177
Analyzed Analyzed - Analysis Complete

SQL Injection in Dell SCG Appliance

Vulnerability report for CVE-2026-80177, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-09-09

Last updated on: 2026-09-09

Assigner: Dell

Description

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to script injection.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-09-09
Last Modified
2026-09-09
Generated
2026-09-29
AI Q&A
2026-09-09
EPSS Evaluated
2026-09-27
NVD
EUVD

Affected Vendors & Products

Showing 2 associated CPEs
Vendor Product Version / Range
dell secure_connect_gateway to 5.36.00.00 (exc)
dell secure_connect_gateway to 5.36.00.16 (exc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-89 The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This is an SQL Injection vulnerability in Dell SCG 5.0 Appliance and Application versions before 5.36.00.16 and 5.36.00.00 respectively. It allows a low-privileged remote attacker to inject malicious SQL commands by sending specially crafted input.

Detection Guidance

Detection of SQL injection vulnerabilities like CVE-2026-80177 typically involves monitoring network traffic for suspicious SQL queries, inspecting application logs for unusual input patterns, and using web application firewalls to block malicious requests. Specific commands depend on your environment, but common tools include SQLmap for testing, Wireshark for network analysis, and log review commands like grep or tail for application logs.

Impact Analysis

An attacker could exploit this to read sensitive data from the database, modify or delete data, or execute administrative operations. This could lead to unauthorized access to confidential information stored in the system.

Compliance Impact

This vulnerability could lead to unauthorized data access or breaches, violating GDPR's data protection requirements and HIPAA's security rules for protected health information. Non-compliance may result in legal penalties and reputational damage.

Mitigation Strategies

Update Dell SCG 5.0 Appliance to version 5.36.00.16 or later and Dell SCG 5.0 Application to version 5.36.00.00 or later to address the SQL injection vulnerability.