CVE-2026-44414
Received Received - Intake

Buffer Overflow in Industrial Edge Devices

Vulnerability report for CVE-2026-44414, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-10-13

Last updated on: 2026-10-13

Assigner: siemens-SADP

Description

A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-10-13
Last Modified
2026-10-13
Generated
2026-10-13
AI Q&A
2026-10-13
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 63 associated CPEs
Vendor Product Version / Range
Siemens Industrial Edge Cloud Device (IECD) 0
Siemens Industrial Edge Device Kit - arm64 V1.10 0
Siemens Industrial Edge Device Kit - arm64 V1.11 0
Siemens Industrial Edge Device Kit - arm64 V1.12 0
Siemens Industrial Edge Device Kit - arm64 V1.13 0
Siemens Industrial Edge Device Kit - arm64 V1.14 0
Siemens Industrial Edge Device Kit - arm64 V1.15 0
Siemens Industrial Edge Device Kit - arm64 V1.16 0
Siemens Industrial Edge Device Kit - arm64 V1.17 0
Siemens Industrial Edge Device Kit - arm64 V1.18 0
Siemens Industrial Edge Device Kit - arm64 V1.19 0
Siemens Industrial Edge Device Kit - arm64 V1.20 0
Siemens Industrial Edge Device Kit - arm64 V1.21 0
Siemens Industrial Edge Device Kit - arm64 V1.22 0
Siemens Industrial Edge Device Kit - arm64 V1.23 0
Siemens Industrial Edge Device Kit - arm64 V1.24 0
Siemens Industrial Edge Device Kit - arm64 V1.25 0
Siemens Industrial Edge Device Kit - arm64 V1.26 0
Siemens Industrial Edge Device Kit - arm64 V1.27 0
Siemens Industrial Edge Device Kit - arm64 V1.28 0
Siemens Industrial Edge Device Kit - arm64 V1.5 0
Siemens Industrial Edge Device Kit - arm64 V1.6 0
Siemens Industrial Edge Device Kit - arm64 V1.7 0
Siemens Industrial Edge Device Kit - arm64 V1.8 0
Siemens Industrial Edge Device Kit - arm64 V1.9 0
Siemens Industrial Edge Device Kit - x86-64 V1.10 0
Siemens Industrial Edge Device Kit - x86-64 V1.11 0
Siemens Industrial Edge Device Kit - x86-64 V1.12 0
Siemens Industrial Edge Device Kit - x86-64 V1.13 0
Siemens Industrial Edge Device Kit - x86-64 V1.14 0
Siemens Industrial Edge Device Kit - x86-64 V1.15 0
Siemens Industrial Edge Device Kit - x86-64 V1.16 0
Siemens Industrial Edge Device Kit - x86-64 V1.17 0
Siemens Industrial Edge Device Kit - x86-64 V1.18 0
Siemens Industrial Edge Device Kit - x86-64 V1.19 0
Siemens Industrial Edge Device Kit - x86-64 V1.20 0
Siemens Industrial Edge Device Kit - x86-64 V1.21 0
Siemens Industrial Edge Device Kit - x86-64 V1.22 0
Siemens Industrial Edge Device Kit - x86-64 V1.23 0
Siemens Industrial Edge Device Kit - x86-64 V1.24 0
Siemens Industrial Edge Device Kit - x86-64 V1.25 0
Siemens Industrial Edge Device Kit - x86-64 V1.26 0
Siemens Industrial Edge Device Kit - x86-64 V1.27 0
Siemens Industrial Edge Device Kit - x86-64 V1.28 0
Siemens Industrial Edge Device Kit - x86-64 V1.5 0
Siemens Industrial Edge Device Kit - x86-64 V1.6 0
Siemens Industrial Edge Device Kit - x86-64 V1.7 0
Siemens Industrial Edge Device Kit - x86-64 V1.8 0
Siemens Industrial Edge Device Kit - x86-64 V1.9 0
Siemens Industrial Edge Own Device (IEOD) 0
Siemens Industrial Edge Virtual Device (IEVD) 0
Siemens SCALANCE LPE9413 0
Siemens SCALANCE LPE9433 0
Siemens SIMATIC IoT2050 Advanced IED 0
Siemens SIMATIC IoT2050 SM IED 0
Siemens SIMATIC IPC BX-21A Industrial Edge Device 0
Siemens SIMATIC IPC BX-39A Industrial Edge Device 0
Siemens SIMATIC IPC BX-59A Industrial Edge Device 0
Siemens SIMATIC IPC127E Industrial Edge Device 0
Siemens SIMATIC IPC227E Industrial Edge Device 0
Siemens SIMATIC IPC227G Industrial Edge Device 0
Siemens SIMATIC IPC427E Industrial Edge Device 0
Siemens SIMATIC IPC847E Industrial Edge Device 0

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-35 The product uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize '.../...//' (doubled triple dot slash) sequences that can resolve to a location that is outside of that directory.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

CVE-2026-44414 is a path traversal vulnerability affecting multiple Siemens Industrial Edge devices. It allows an authenticated remote attacker to access sensitive internal information by exploiting improperly restricted access to internal APIs and paths. This could potentially lead to unauthorized system access in severe cases.

Detection Guidance

Detecting this vulnerability requires checking for improperly restricted internal APIs and paths. Use network scanning tools like nmap to identify exposed services on affected Siemens Industrial Edge devices. Check for unusual API endpoints or file paths that may allow unauthorized access. Review system logs for suspicious authenticated remote access attempts to internal resources.

Impact Analysis

An attacker could exploit this to access sensitive internal data, which may include system configurations or credentials. In the worst case, this could facilitate unauthorized access to the system, potentially disrupting operations or leading to data breaches.

Compliance Impact

This vulnerability could lead to unauthorized access to sensitive data, which may violate compliance requirements under GDPR, HIPAA, or other regulations. Unauthorized data exposure or access could result in legal penalties, fines, or reputational damage.

Mitigation Strategies
  • Update affected Siemens Industrial Edge Device Kit versions to V1.26.2-1 or later for arm64/x86-64, V1.27.1-1 or later for arm64/x86-64, and V1.28.0-6 or later for arm64/x86-64.
  • For products without available fixes, limit network access to trusted parties and follow general security measures.
  • Apply Siemens recommended mitigations for Industrial Edge Cloud Device (IECD), Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413, SCALANCE LPE9433, SIMATIC IoT2050 devices, and SIMATIC IPC Industrial Edge Devices.