A vulnerability has been identified in .NET Client Library for SIMATIC S7 Webserver API (All versions < V3.3.61). Affected applications do not properly validate filenames received from remote servers during ticket downloads. This could allow an attacker who can manipulate the ticket response to write arbitrary files outside the intended download directory and, when overwriting is enabled, replace existing files accessible to the application.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-10-13
Last Modified
2026-10-13
Generated
2026-10-13
AI Q&A
2026-10-13
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
Siemens .NET Client Library for SIMATIC S7 Webserver API 0

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-22 The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This is a path traversal vulnerability in the .NET Client Library for SIMATIC S7 Webserver API. It occurs because the library fails to properly validate filenames received from remote servers during ticket downloads. An attacker who can manipulate ticket responses could write arbitrary files outside the intended download directory or overwrite existing files accessible to the application.

Detection Guidance

To detect this vulnerability, check if your .NET Client Library for SIMATIC S7 Webserver API is running a version older than V3.3.61. Inspect network traffic for unusual file download requests or responses that include path traversal sequences like '../'. Monitor file system changes outside the intended download directory.

Impact Analysis

This vulnerability could allow an attacker to overwrite critical files, disrupt operations, or execute malicious code on systems using the affected library. It may lead to unauthorized data access, system compromise, or denial of service if exploited.

Compliance Impact

This vulnerability could lead to unauthorized file writes or overwrites outside intended directories, potentially exposing sensitive data. This may violate compliance requirements for data protection such as GDPR (data integrity and confidentiality) and HIPAA (secure handling of protected health information) by enabling unauthorized access or modification of critical files.

Mitigation Strategies

Update the .NET Client Library for SIMATIC S7 Webserver API to version V3.3.61 or later as recommended by Siemens to address the path traversal vulnerability.