CVE-2026-87675
Received
Received - Intake
Command Injection in Brocade Fabric OS
Vulnerability report for CVE-2026-87675, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.
Publication date: 2026-10-08
Last updated on: 2026-10-08
Assigner: Brocade Communications Systems, LLC
Description
Description
An OS command injection vulnerability exists in the configuration management subsystem of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. When performing a configuration download operation, the management daemon will relay configuration parameters, user-supplied relay host strings, and filenames directly to an internal utility script without sufficient character set validation. Because the local utility fails to sanitize shell metacharacters before processing them in a system shell command, a malicious or compromised configuration file can cause arbitrary operating system commands to be executed on a remote local switch when an administrator initiates a configuration download.
CVSS Scores
EPSS Scores
| Probability: | |
| Percentile: |
Meta Information
Affected Vendors & Products
| Vendor | Product | Version / Range |
|---|---|---|
| Brocade | Fabric | OS 0 |
| Brocade | Fabric | OS 10.0.0 |
Helpful Resources
Exploitability
| CWE ID | Description |
|---|---|
| CWE-78 | The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component. |