CVE-2026-121024
Received Received - Intake

Incorrect Authorization in AxxonNet Health Monitoring Service

Vulnerability report for CVE-2026-121024, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-11-03

Last updated on: 2026-11-03

Assigner: AxxonSoft

Description

Incorrect Authorization (CWE-863) in the Health Monitoring service in AxxonSoft AxxonNet before 3.28.0 on Linux allows a remote attacker in possession of a shared report token, which is intended for read-only access, to create, modify or delete monitoring alerts via the monitoring API.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-11-03
Last Modified
2026-11-03
Generated
2026-11-03
AI Q&A
2026-11-03
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
AxxonSoft AxxonNet 0

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-863 The product performs an authorization check when an actor attempts to access a resource or perform an action, but it does not correctly perform the check.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This vulnerability is an Incorrect Authorization issue (CWE-863) in AxxonSoft AxxonNet before version 3.28.0 on Linux. It allows a remote attacker with a shared report token, meant for read-only access, to misuse the monitoring API to create, modify, or delete monitoring alerts.

Detection Guidance

This vulnerability involves incorrect authorization in AxxonSoft AxxonNet before version 3.28.0. Detection requires checking the installed version of AxxonNet and verifying if the Health Monitoring service is exposed to unauthorized API access. No specific commands are provided in the context.

Impact Analysis

An attacker could manipulate monitoring alerts, potentially leading to undetected system issues or false alarms. This could disrupt health monitoring services and compromise system reliability.

Mitigation Strategies

Immediately upgrade AxxonSoft AxxonNet to version 3.28.0 or later to address the incorrect authorization issue. Ensure the Health Monitoring service is not exposed to untrusted networks and restrict API access to authorized users only.