CVE-2026-124477
Received Received - Intake

OpenEMR Missing Authorization in Patient Recall Deletion

Vulnerability report for CVE-2026-124477, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-11-08

Last updated on: 2026-11-08

Assigner: VulnCheck

Description

OpenEMR before 8.3.0 contains a missing authorization vulnerability that allows low-privileged authenticated users to delete arbitrary patient recall records via the delete_Recall action. Attackers can send POST requests to /interface/main/messages/save.php with a target pid and r_ID to remove recall data without ACL or ownership checks.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-11-08
Last Modified
2026-11-08
Generated
2026-11-08
AI Q&A
2026-11-08
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
openemr openemr to 8.3.0 (exc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-862 The product does not perform an authorization check when an actor attempts to access a resource or perform an action.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

OpenEMR before version 8.3.0 has a missing authorization flaw. Low-privileged authenticated users can delete any patient recall records by sending a POST request to /interface/main/messages/save.php with specific parameters (pid and r_ID). The system fails to perform access control list (ACL) or ownership checks, allowing unauthorized data deletion.

Detection Guidance

Check OpenEMR logs for POST requests to /interface/main/messages/save.php with delete_Recall action and parameters pid and r_ID. Monitor for unauthorized deletion of patient recall records by low-privileged users.

Impact Analysis

This vulnerability allows attackers with low privileges to delete critical patient recall records, potentially disrupting medical follow-ups, treatment schedules, or compliance reporting. It compromises data integrity and could lead to patient safety risks or legal consequences if recalls are missed.

Compliance Impact

This vulnerability likely violates data integrity and access control requirements under GDPR (Article 5) and HIPAA (Security Rule). Unauthorized deletion of patient recall data could result in non-compliance, leading to fines, legal penalties, or loss of certification for healthcare providers.

Mitigation Strategies

Upgrade OpenEMR to version 8.3.0 or later. Implement strict ACL checks for delete_Recall actions. Review and restrict user permissions to prevent unauthorized data deletion.