Description

An incorrect permission assignment vulnerability in Omada SDN Controller prior to 6.2.20 may cause a database backup generated during the uninstall workflow to remain readable by other local users on the host.Β  Successful exploitation requires local, low-privileged access to the affected host and a retained uninstall backup. An attacker meeting these conditions could access the backup and disclose controller data without controller credentials.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-11-18
Last Modified
2026-11-18
Generated
2026-11-19
AI Q&A
2026-11-19
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
TP-Link Systems Inc. Omada SDN Controller From 0 (inc) to 6.2.20 (exc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-732 The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This vulnerability is an incorrect permission assignment issue in Omada SDN Controller versions prior to 6.2.20. It allows a database backup created during the uninstall process to remain readable by other local users on the host system.

Detection Guidance

This vulnerability requires local access to the host and a retained uninstall backup. Check for unauthorized access to backup files in Omada SDN Controller directories, particularly after uninstallation. Look for files with sensitive controller data outside expected secure locations.

Impact Analysis

An attacker with local low-privileged access and access to the uninstall backup could read the backup and disclose sensitive controller data without needing valid credentials. This could lead to unauthorized data exposure.

Compliance Impact

This vulnerability could lead to unauthorized access to sensitive data, potentially violating data protection regulations like GDPR or HIPAA by exposing personal or health information without proper authorization.

Mitigation Strategies

Upgrade Omada SDN Controller to version 6.2.20 or later to address the incorrect permission assignment vulnerability.