CVE-2026-125612
Received Received - Intake

SQL Injection in Deltaww DIAEnergie

Vulnerability report for CVE-2026-125612, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.

Publication date: 2026-11-10

Last updated on: 2026-11-10

Assigner: Deltaww

Description

Improper neutralization of special elements used in an SQL command ('SQL injection') vulnerability in Deltaww DIAEnergie allows SQL Injection. This issue affects DIAEnergie: before 1.11.01.032.

CVSS Scores

EPSS Scores

Probability:
Percentile:

Meta Information

Published
2026-11-10
Last Modified
2026-11-10
Generated
2026-11-10
AI Q&A
2026-11-10
EPSS Evaluated
N/A
NVD
EUVD

Affected Vendors & Products

Showing 1 associated CPE
Vendor Product Version / Range
Deltaww DIAEnergie From 0 (inc) to 1.11.1.32 (exc)

Helpful Resources

Exploitability

CWE
CWE Icon
KEV
KEV Icon
CWE ID Description
CWE-89 The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data.

Attack-Flow Graph

AI Quick Actions

Instant insights powered by AI
Executive Summary

This is an SQL injection vulnerability in Deltaww DIAEnergie software versions before 1.11.01.032. It allows attackers to inject malicious SQL commands into the application, potentially accessing, modifying, or deleting database contents without proper authorization.

Detection Guidance

Detecting SQL injection vulnerabilities like CVE-2026-125612 typically involves monitoring network traffic for suspicious SQL queries or using web application firewalls. Check for unusual database access patterns or errors in logs. Delta recommends isolating control systems and using firewalls to limit exposure.

Impact Analysis

An attacker could exploit this to read sensitive data, alter or delete database records, gain administrative access, or execute system commands. This could lead to data breaches, system outages, or unauthorized control of the affected software.

Compliance Impact

This vulnerability could lead to non-compliance with GDPR (data protection), HIPAA (health data security), or other regulations by enabling unauthorized access to sensitive data. Organizations may face legal penalties, fines, or reputational damage if exploited.

Mitigation Strategies

Upgrade DIAEnergie to version v1.11.01.032 or later. Contact Delta technical support for assistance. Isolate control systems from the internet, use firewalls, and employ secure remote access methods like VPNs.