CVE-2026-94460
Received
Received - Intake
IRISPowerscan Insecure Default Credentials Allow Privileged Access
Vulnerability report for CVE-2026-94460, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.
Publication date: 2026-11-04
Last updated on: 2026-11-04
Assigner: Canon_EMEA
Description
Description
IRISPowerscan contain an insecure default
configuration where the built-in installation account is assigned elevated
privileges with a predictable password, which could allow an unauthenticated
attacker to gain unauthorised access to privileged application functionality.
CVSS Scores
EPSS Scores
| Probability: | |
| Percentile: |
Meta Information
Affected Vendors & Products
| Vendor | Product | Version / Range |
|---|---|---|
| I.R.I.S S.A. | IRISPowerscan | 0 |
Helpful Resources
Exploitability
| CWE ID | Description |
|---|---|
| CWE-276 | During installation, installed file permissions are set to allow anyone to modify those files. |