CVE-2024-8956
Unknown
Unknown - Not Provided
BaseFortify
Vulnerability report for CVE-2024-8956, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.
Publication date: 2024-09-17
Last updated on: 2025-10-27
Assigner: VulnCheck
Description
Description
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
CVSS Scores
EPSS Scores
| Probability: | |
| Percentile: |
Meta Information
Affected Vendors & Products
| Vendor | Product | Version / Range |
|---|---|---|
| ptzoptics | pt30x-sdi_firmware | to 6.3.40 (exc) |
| ptzoptics | pt30x-sdi | * |
| ptzoptics | pt30x-ndi-xx-g2_firmware | to 6.3.40 (exc) |
| ptzoptics | pt30x-ndi-xx-g2 | * |
Helpful Resources
Exploitability
| CWE ID | Description |
|---|---|
| CWE-287 | When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct. |
| CWE-306 | The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources. |