CVE-2024-8957
Unknown
Unknown - Not Provided
BaseFortify
Vulnerability report for CVE-2024-8957, including description, CVSS score, EPSS score, affected products, exploitability, helpful resources, and attack-flow context.
Publication date: 2024-09-17
Last updated on: 2025-10-27
Assigner: VulnCheck
Description
Description
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.
CVSS Scores
EPSS Scores
| Probability: | |
| Percentile: |
Meta Information
Affected Vendors & Products
| Vendor | Product | Version / Range |
|---|---|---|
| ptzoptics | pt30x-sdi_firmware | to 6.3.40 (exc) |
| ptzoptics | pt30x-sdi | * |
| ptzoptics | pt30x-ndi-xx-g2_firmware | to 6.3.40 (exc) |
| ptzoptics | pt30x-ndi-xx-g2 | * |
Helpful Resources
Exploitability
| CWE ID | Description |
|---|---|
| CWE-78 | The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component. |